China
15-25 dyas
FOB/CIF/CFR/EXW
siliver
fan shaft
1. Brief details:
Material of the fan shaft: C45 top grade steel.
Size of the fan shaft: (Diameter and length can be customerized or do as sample or artworks.).
Packing: 50pcs/poly bag, and 400pcs/carton.
Lead time: 20 days
FOB Port: GUANGZHOU, ZHONGSHAN, SHENZHEN etc.
MOQ: 5000PCS/Model
Free design and free samples.
2. Picture of the fan shaft:


3. fan shaft OEM/ODM is welcomed.
We will provide with free quotations, free solutions, and free samples.
4. Production pictures for the fan shaft in the production:

5. Packings: for fan shaft, we use poly bags and cartons to pack:

6. Delivery and container loading:
We have professional team for container loading, to make sure the container loading net and clean. At the same time , make sure the safty of the fan motors.


7. We provide services for producing and purchasing other parts for electric fan motor and fans for all customers. Such as: fan motor stators, fan motor covers, fan shaft clips, and other parts. To load together in our factory, and lower the cost of the time and money of all customers and friends!
FAQ:
This is a copy of catalog.
Our products have sold in a number of areas abroad. They are very popular with the users there
Can I buy samples placing orders?
Yes.Please feel free to contact us.
How To Order ?
Step 1, please tell us what model and quantity you need;
Step 2, then we will make a PI for you to confirm the order details;
Step 3, when we confirmed everything, can arrange the payment;
Step 4, finally we deliver the goods within the stipulated time.
When will make delivery ?
Delivery Time
-Sample Order: 3-7 days after receipt of the full payment.
-Stock Order: 7-15days after receipt of the full payment
-OEM Order: 15-25days after receipt of the deposit.
After-sales Service
1 year warranty for all kinds of products;
If you find any defective accessories first time, we will give you the new parts for free to replace in the next order, as an experienced manufacturer, you can rest assured of the quality and after-sales service.
This guide breaks down the differences between shaded-pole and capacitor-run PSC motors for kitchen range hoods, helping OEM and replacement buyers select based on airflow, load, noise and cost.
Sourcing an exact drop-in replacement AC fan motor for 12", 16", and 18" table or wall fans requires matching five mechanical and electrical parameters: (1) Shaft Diameter (typically Ø8.0 mm) and usable extension length(2) Stator Core Stack Dimensions(3) Mounting Stud Pitch / Rear Bracket Pattern(4
This article introduces three vital AC fan motor components: end cover, housing and bracket. Often ignored by buyers, these stamped parts determine vibration, noise, bearing life and corrosion resistance. It covers their functions, material choices and the popular integrated end cover & bracket design for shaded pole motors. A material selection guide, QC rules and OEM service are included for sourcing custom parts or full motors.
When a fan motor fails and the nameplate is burnt, missing, or printed in an unfamiliar code, a fan motor replacement does not have to wait for a part number. Six measurements — shaft diameter, shaft length, mounting hole pattern, body diameter and length, lead exit and stack thickness — plus a resistance reading across each winding tap will identify a drop-in match. This guide explains what to measure, which tolerances actually matter, why rotation cannot be reversed by swapping wires, and how to order from a photo.
Fan motor shaft and bushing assemblies ensure precise torque transmission and dynamic balance in small AC motors (CBB61, shaded pole, cross-flow blowers). Used in table, pedestal, wall, bathroom and industrial exhaust fans and range hoods, with shafts Ø5.0–20.0 mm ground to ISO h6/h7. Options: D-cuts, knurling, threads, circlip grooves, keyways. Materials: AISI 1045 steel with nickel/zinc plating (≥48-hour salt spray) or non-magnetic SUS303/304 stainless for coastal/humid use. Selective induction hardening (45–55 HRC) at bearing seats extends wear life. Suits SAE 841 bushings and 608/6000/6200-2RS ball bearings.
This guide explains why shaded pole motors with identical nameplates vary widely in service life, citing system resistance, ambient temperature, 50/60 Hz traps, and shaft orientation. It covers load curves, impeller power, and sleeve vs. ball bearings, offering a 10-point checklist to specify the right motor, prevent early failures, and optimize total cost of ownership.
On a scorching summer day, flip the fan switch and the blades instantly spin, filling the room with a cool breeze. This effortless, one-second "start-up-airflow" process, however, hides a crucial question: How exactly is electrical energy converted into the power that drives the blades? The answer l
Centered on commercial exhaust motors (12–16 hrs/day at 60–70°C with grease), this article contrasts household hood, oven, and air-fryer motors. It details how duty cycle and exposure drive specs, with a checklist and schedule.
Fan motor sourcing in Southeast Asia and the Middle East starts with frequency, not price. The Philippines and Saudi Arabia run on 60Hz grids; a 50Hz motor run directly on 60Hz spins about 20% faster and is asked for roughly 70% more shaft power, which means overheating and short life. Environment comes second — coastal salt fog and humidity attack insulation, Gulf sand and 50°C heat attack bearings and windings. The guide gives a six-line RFQ checklist, the IP54/IP55 rule for Gulf outdoor exhaust fans, and the buyer-behavior differences between the two regions.
In Indonesia, Vietnam and the Philippines, repair-market buying decisions are made at the workbench, with the old motor in hand. What wins is dimensional fit, model coverage and replenishment speed — not the numbers on a power table. This is how we structure our quotations and shipments.
| 206,207,208, No. 4, Lijun Road, Xili Industrial Zone, Shatou Street, Guangzhou, Guangdong, China |
