| Voltage: | |
|---|---|
| Power: | |
| Shaft: | |
| Availability: | |
YJ48-20
YKFANMOTOR
Baking oven, steam oven, fan heater, refrigerator, display cabinet
Stator 48x20mm, shaft 4mm
Pure copper / aluminium wire
AC 208-230/240V, 50Hz
15W
2800 RPM
Class F
The YKFANMOTOR YJ48-20 is a 15 W single-phase shaded pole motor with a double shaft, built to drive the convection fan in baking ovens, steam ovens and fan heaters. It runs on 208–230/240 V at 50 Hz, reaches 2,800 RPM, and uses Class F insulation with a 48 × 20 mm stator and a 4 mm shaft.
Double shaft. Both ends of the rotor are extended, so one motor can drive the convection impeller and a second element such as a cooling fan or coupling on the same axis.
Class F insulation. Oven cavities soak the motor in hot air even after the element switches off; Class F windings hold their rating far better than Class B in that environment.
No capacitor. Shaded pole construction starts directly from the mains, which removes a heat-sensitive component from inside the oven shell.
2,800 RPM on a 20 mm stack. A compact, shallow build for slim oven backs where a longer motor will not fit behind the cavity panel.
OEMs building built-in baking ovens, steam ovens, convection heaters and display cabinets, plus aftermarket suppliers stocking oven fan motors for repair channels.
For refrigerated display and fresh cabinet cooling see the fresh cabinet motor range. For higher-temperature cavities and longer duty cycles see our oven motor series.
Parameter | Value |
|---|---|
Motor type | Single-phase shaded pole induction motor |
Model | YJ48-20 |
Shaft configuration | Double shaft |
Rated voltage | AC 208–230/240 V |
Frequency | 50 Hz |
Phase | Single-phase |
Rated power | 15 W |
Rated speed | 2,800 RPM |
Insulation class | Class F |
Wire winding material | Pure copper / aluminium wire |
Efficiency class | IE1 |
Rotation | CW standard, CCW available on request |
Stator size | 48 × 20 mm |
Shaft diameter | 4 mm |
Certification | CE, RoHS, ISO 9001 |
Place of origin | Guangdong, China |
MOQ | 1,000 pcs |
Lead time | 20 days (1–10,000 pcs), 25 days (10,001–50,000 pcs) |
Warranty | 2 years |
Shaft extension at both ends, keyway, flat and lead-wire length are produced to your drawing. Voltage can be customized from 1,000 pcs.
Built-in baking ovens and convection ovens
Steam ovens and combination steamers
Fan heaters and convection heaters
Refrigerators and refrigerated display cabinets
Three parameters decide whether a shaded pole motor survives inside an oven: insulation class, bearing type and thermal protection. This model covers the first with Class F windings and a 20 mm stack that keeps the winding away from the cavity wall. Confirm the following with your thermal test data:
Ambient at the motor flange during the longest cooking cycle, not just the cavity set point.
Bearing choice for horizontal or vertical mounting — state the mounting orientation when ordering.
Rotation and shaft length at both ends, since the second shaft drives a separate element.
Seal the shaft pass-through against steam ingress on steam oven builds. The drip-proof frame protects against splash and condensation, not continuous steam exposure.
Voltage: customized AC voltage from 1,000 pcs
Wire: pure copper or aluminium, specified against duty cycle and cost target
Shaft: extension length, flat, keyway or spline at either end
Rotation: CW standard, CCW built on request
Lead wire and connector: high-temperature cable and terminal type for oven wiring
Branding: nameplate and packaging to your specification
Send the oven drawing, motor mounting envelope and thermal data.
We confirm winding wire, bearing, shaft geometry and price.
Sample is validated in your cavity test.
Production runs at 20 days for 1–10,000 pcs.
Minimum order quantity is 1,000 pcs; warranty 2 years. The factory is ISO 9001 certified and has more than 28 years of motor design and production experience.
The rotor shaft extends from both ends of the motor, so the convection impeller can be fitted on one side and a second fan or coupling on the other.
Yes, CCW is available on request. CW is the standard build.
Class F, which is the minimum we recommend for oven cavities. For higher ambient temperatures, specify the Class H builds in our oven motor range.
No capacitor is needed. This is a shaded pole motor and runs directly from the AC supply.
1,000 pcs; 20 days for 1–10,000 pcs and 25 days for 10,001–50,000 pcs.
Yes, AC voltage can be customized from 1,000 pcs. The standard build is 208–230/240 V 50 Hz.
Centered on commercial exhaust motors (12–16 hrs/day at 60–70°C with grease), this article contrasts household hood, oven, and air-fryer motors. It details how duty cycle and exposure drive specs, with a checklist and schedule.
Fan motor sourcing in Southeast Asia and the Middle East starts with frequency, not price. The Philippines and Saudi Arabia run on 60Hz grids; a 50Hz motor run directly on 60Hz spins about 20% faster and is asked for roughly 70% more shaft power, which means overheating and short life. Environment comes second — coastal salt fog and humidity attack insulation, Gulf sand and 50°C heat attack bearings and windings. The guide gives a six-line RFQ checklist, the IP54/IP55 rule for Gulf outdoor exhaust fans, and the buyer-behavior differences between the two regions.
In Indonesia, Vietnam and the Philippines, repair-market buying decisions are made at the workbench, with the old motor in hand. What wins is dimensional fit, model coverage and replenishment speed — not the numbers on a power table. This is how we structure our quotations and shipments.
Standard motors tested at room temperature (25℃) often fail during their first summer in the Gulf. At 50℃ ambient, a standard Class F motor operates at its absolute limit with zero safety margin. The proven fix requires either output derating or upgrading to Class H insulation, paired with 105℃-rated capacitors and high-temperature polyurea/lithium grease.
Motors in the Gulf don't usually fail because the copper wire burned out. Sand kills the bearings first. To make your fans last in Saudi Arabia, UAE, or Iraq, you need the right shaft seals and proper IP ratings based on where the fan is actually installed.
A 50Hz fan motor on a 60Hz grid runs ~20% faster, demanding ~73% more impeller power — so it burns out by the first hot season in the Philippines and Saudi Arabia. This post explains the physics simply, compares relabel vs dual-rated vs genuine 60Hz winding, contrasts PH and KSA thermal demands, lists YKFANMOTOR's 60Hz deliverables, and closes with an FAQ.
Coastal Southeast Asia breaks fan motors in three predictable ways: moisture in the winding, salt fog on the shaft and terminals, and low grid voltage that kills starting torque. None of these is fully avoidable — but most of the risk can be designed out at the specification stage. This guide walks through the failure mechanisms, the practical countermeasures, and a checklist you can use with your supplier.
This post explains how importers set up a 220V/60Hz fan motor OEM programme for Saudi Arabia — clarifying that the issue is frequency specification, not motor quality. It covers the frequency problem, 127V as a separate SKU, three OEM levels, the SABER document chain, high-ambient design requirements, commercial terms, and a condensed capability list with three items needed to quote.
Sourcing a custom fan motor requires more than just comparing unit prices. This ultimate OEM/ODM checklist outlines the 5 key evaluation criteria, 10 vital vetting questions, customization scopes, and practical ways to prevent quality drift for your appliance project.
Wondering why some fan motors fail prematurely while others run reliably for years? Frame size and wattage don't tell the whole story. This guide breaks down the four core components—laminated stators/rotors, copper windings, precision shafts, and high-performance bearings—that dictate true motor lifespan and how B2B buyers can inspect them to prevent costly warranty returns.
| 206,207,208, No. 4, Lijun Road, Xili Industrial Zone, Shatou Street, Guangzhou, Guangdong, China |