Combining an 80W power rating with a streamlined aluminum wire configuration, the 6820 AC Shaded Pole Motor offers the perfect balance between cost-efficiency and reliable suction performance for modern cooker hoods. It is engineered specifically for high-demand household ventilation.
| Precision Balanced Power Unit | Precision-balanced rotor with anti-vibration bracket and self-lubricating bearings delivers ultra-quiet, low-vibration operation and lasting durability even at high speeds. |
| Efficient Magnetic Circuit Design | High-grade silicon steel stator + Class B heat-resistant enameled copper coil ensure efficient magnetic circuit performance and stable, reliable insulation. |
| Integrated Safety & Speed Control | Built-in 120°C auto-reset thermal protector, paired with 6.3mm plug-in terminals for 3-speed adjustment, balances operational safety with easy wiring. |
Parameter | Specification | Parameter | Specification |
Model | YK6820-80 | Type | 6820 AC Shaded Pole Motor |
Material | Aluminum Wire Stator (Cost-effective) | Bearing Type | Oil-impregnated Bushings |
Voltage/Frequency | AC 220V/50Hz | Power | 80W |
Speed | 3 Speed | Rotation Speed(RPM) | 2770r/min-2990r/min(No-load) |
Rotation Direction | CCW (Counter-Clockwise from Shaft End) | Insulation Clas | Class B |
Temperature Rise | <120K | Flame Retardancy | V0 Level |
Thermal Protector | HK-W 9700 120°C | Certification | CE, RoHS, ISO |
Primarily designed for Household / Commercial Cooker Hoods
Q: Can the stator be upgraded to copper wire?
A: Yes, we offer both aluminum and copper wire options based on your budget and performance requirements.
Q: Do you support small batch OEM orders?
A: Absolutely. We provide flexible MOQ options for customized branding and technical adjustments.
On a scorching summer day, flip the fan switch and the blades instantly spin, filling the room with a cool breeze. This effortless, one-second "start-up-airflow" process, however, hides a crucial question: How exactly is electrical energy converted into the power that drives the blades? The answer l
Centered on commercial exhaust motors (12–16 hrs/day at 60–70°C with grease), this article contrasts household hood, oven, and air-fryer motors. It details how duty cycle and exposure drive specs, with a checklist and schedule.
Fan motor sourcing in Southeast Asia and the Middle East starts with frequency, not price. The Philippines and Saudi Arabia run on 60Hz grids; a 50Hz motor run directly on 60Hz spins about 20% faster and is asked for roughly 70% more shaft power, which means overheating and short life. Environment comes second — coastal salt fog and humidity attack insulation, Gulf sand and 50°C heat attack bearings and windings. The guide gives a six-line RFQ checklist, the IP54/IP55 rule for Gulf outdoor exhaust fans, and the buyer-behavior differences between the two regions.
In Indonesia, Vietnam and the Philippines, repair-market buying decisions are made at the workbench, with the old motor in hand. What wins is dimensional fit, model coverage and replenishment speed — not the numbers on a power table. This is how we structure our quotations and shipments.
Standard motors tested at room temperature (25℃) often fail during their first summer in the Gulf. At 50℃ ambient, a standard Class F motor operates at its absolute limit with zero safety margin. The proven fix requires either output derating or upgrading to Class H insulation, paired with 105℃-rated capacitors and high-temperature polyurea/lithium grease.
Motors in the Gulf don't usually fail because the copper wire burned out. Sand kills the bearings first. To make your fans last in Saudi Arabia, UAE, or Iraq, you need the right shaft seals and proper IP ratings based on where the fan is actually installed.
A 50Hz fan motor on a 60Hz grid runs ~20% faster, demanding ~73% more impeller power — so it burns out by the first hot season in the Philippines and Saudi Arabia. This post explains the physics simply, compares relabel vs dual-rated vs genuine 60Hz winding, contrasts PH and KSA thermal demands, lists YKFANMOTOR's 60Hz deliverables, and closes with an FAQ.
Coastal Southeast Asia breaks fan motors in three predictable ways: moisture in the winding, salt fog on the shaft and terminals, and low grid voltage that kills starting torque. None of these is fully avoidable — but most of the risk can be designed out at the specification stage. This guide walks through the failure mechanisms, the practical countermeasures, and a checklist you can use with your supplier.
This post explains how importers set up a 220V/60Hz fan motor OEM programme for Saudi Arabia — clarifying that the issue is frequency specification, not motor quality. It covers the frequency problem, 127V as a separate SKU, three OEM levels, the SABER document chain, high-ambient design requirements, commercial terms, and a condensed capability list with three items needed to quote.
Sourcing a custom fan motor requires more than just comparing unit prices. This ultimate OEM/ODM checklist outlines the 5 key evaluation criteria, 10 vital vetting questions, customization scopes, and practical ways to prevent quality drift for your appliance project.
| 206,207,208, No. 4, Lijun Road, Xili Industrial Zone, Shatou Street, Guangzhou, Guangdong, China |